Junction Box
Hydraulic Unit
Hydraulic Pump
H8050 DC Powered Pump
Vehicle Loop Detectors |
Delta supplies
standard and custom control circuitry
to operate single or multiple barricade
systems. We
also use programmable logic controllers
(PLC) for special applications to time
and coordinate gates, signal early
warning systems, safety interlocks
and multiple operating modes. International
voltages are available.
|
Junction
Box and Control Circuitry top
This photograph shows a typical two barricade
control circuit with an integral motor
starter, electrical disconnect and step
down transformer.
We build control circuits to project
requirements from the simple to highly
complex integrated systems controlling
multiple barricade systems. International
voltages are available. |
Hydraulic
Power Unit – Skid Mounted
for Big Equipment top
This is the top of the line, heavy duty,
patented Delta Power Unit. We
rack and stack valves, flow controls
and accumulators to meet our client’s
applications for speed of operation,
number of barricades to be controlled
and the number of power off cycles required.
The pump is supplied with an integral
tank, sight gage and level switch. Options
include hand pump and oil heater. The
unit shown is a two barricade system
pump.
|

Hydraulic
Pump Control Equipment and Housing
for Smaller Equipment top
Pictured is the patented Delta Beta pump,
a scaled-down version of the Delta Power
Unit. It
is used for our medium to small barricades,
depending on site conditions, barricade
selection and speed of operation requirements. |
H8050
DC Powered Pump top
Universal voltage DC powered versions
(Model H8050)
of these pumps are available for remote
locations or infrequently operated
barricades. They feature
long battery life, low amperage trickle
charging and solar panel charging.
H8050
Spec Sheet (Word doc) |
Vehicle
Loop Detectors top
Recommending
its use with all Delta and most other
vehicle access control systems, Delta
Scientific’s NP Series Digital
Loop Detectors are programmed to prevent
a closing signal when power is resumed. NP
Series Loop Detectors are directly interchangeable
with most other brands as a plug-in replacement.
These loop detectors provide customers
with a safety detector that can prevent
accidents which occur when power
outages cause vehicle access control
systems to reset their logic. The
3446 NP Series incorporates an advanced
micro-controller that combines a
powerful digital computer and the
latest and most advanced inductive
vehicle loop technology to give high-test
reliability and accuracy when measuring,
counting or detecting vehicles.
This ability helps avoid unexpected
gate operations such as the raising
or lowering of gate arms, sliding gate
operation, motorized teeth and barricade
actuation. Delta
highly suggests and is seeing a wider
application of vehicle loop detectors
to suppress the operation of heavy
gates and vehicle barricades to prevent
accidental closings or raisings when
authorized vehicles move through vehicle
access control systems.
Typical digital loop detectors hold
a gate open until the last part of
a vehicle has passed the closing loop,
located beyond the gate. The
detector then gives a pulse on departure,
instructing the gate to close after
the vehicle has passed. Oftentimes,
after power outages, the entire system
needs to be reset. The NP Series negates
this problem.
Delta NP Series Loop Detectors provide
input voltages of 24 VAC, 24 VDC, 120
VAC and 230 VAC. |
 |
 |
 |
Examples of Delts’a p and p touch screen control panels. |
|
120
Volts, Alternating Current
And Dual Relay Version |
|
3546-3NP |
FEATURES:
Configured not to generate a
pulse when initial power up or
power resumption occurs. This
can avoid unexpectd gate operations
(raising or lowering of gate
arms, sliding gate operation,
motorized teeth and barricade
actuation). Recommended for use
with ALL of DELTA' S vehicle
access control equipment and
most other manufacturers. This
is a direct replacement of a
Delta model 3546-3 where power
resumption safety is desired.
See instructions for complete
infomation. |
See order form for prices |
24
Volts, Alternating Current
And Dual Relay Version |
|
3546-7NP |
FEATURES:
Configured not to generate a
pulse when initial power up or
power resumption occurs. This
can avoid unexpectd gate operations
(raising or lowering of gate
arms, sliding gate operation,
motorized teeth and barricade
actuation). Recommended for use
with ALL of DELTA' S vehicle
access control equipment and
most other manufacturers. This
is a direct replacement of a
Delta model 3546-7 where power
resumption safety is desired.
See instructions for complete
infomation. |
See order form for prices |
220-240
Volts, Alternating Current
And Dual Relay Version |
|
3546-8NP |
FEATURES:
Configured not to generate a
pulse when initial power up or
power resumption occurs. This
can avoid unexpectd gate operations
(raising or lowering of gate
arms, sliding gate operation,
motorized teeth and barricade
actuation). Recommended for use
with ALL of DELTA' S vehicle
access control equipment and
most other manufacturers. This
is a direct replacement of a
Delta model 3546-8 where power
resumption safety is desired.
See instructions for complete
infomation. |
See order form for prices |
120
Volts, Alternating Current
And Dual Relay Version |
|
3546-1 |
FEATURES:
Presence relay is normally open
or normally closed. Normally
open pulse relay with pulse on
arrival. Pulse relay can be set
to pulse on departure. This detector
has a 10-pin Amphenol military
connector. Direct replacement
for the APD detector and Delta
816-1 and 816-12. |
See order form for prices |
120
Volts, Alternating Current
with 3ft Cord And Three Prong
Plug |
|
3546-2 |
FEATURES:
Dual relay version with standard
11-pin male connector. Presence
relay is normally open or normally
closed. Normally open pulse relay
on arrival. Pulse relay can be
set to pulse on departure. It
can also be used as a direct
replacement for Delta 816-2 and
Cincinnati. |
See order form for prices |
120
Volts, Alternating Current
And Single Relay Version |
|
3546-3* |
FEATURES:
Standard 11-pin male connector.
Presence relay is normally open
or normally closed. Normally
open pulse relay with pulse on
arrival. Pulse relay can be set
to pulse on departure. It can
be used as a direct replacement
for the original Sarasota detector
and Delta 816-3 or 816-11.
*This is the most commonly specified
detector. |
See order form for prices |
120
Volts, Alternating Current
And Dual Relay Version |
|
3546-4 |
FEATURES:
Presence relay is normally open
and normally closed. Relay can
be set to a pulse function on
arrival or departure. Direct
replacement for Delta 816-4 and
DECA. |
See order form for prices |
24
Volts, Alternating Current
And Single Relay Version |
|
3546-6 |
FEATURES:
Standard 11-pin male connector.
Presence normally open and nomally
closed. Relay can be set to a
pulse function on arrival or
departure. Direct replacement
for Delta 816-6. |
See order form for prices |
24
Volts, Alternating Current
And Dual Relay Version |
|
3546-7 |
FEATURES:
Standard 11-pin male connector.
Presence normally open and nomally
closed. Relay can be set to a
pulse function on arrival or
departure. Direct replacement
for Delta 816-7. |
See order form for prices |
220-240
Volt, Alternating Current And
Dual Relay Version |
|
3546-8 |
FEATURES:
Standard 11-pin male connector.
Presence normally open and nomally
closed. Normally open pulse relay
with pulse on arrival.Pulse relay
can be set to pulse on departure. |
See order form for prices |
120
Volts, Alternating Current
And Dual Relay Version |
|
3546-9 |
FEATURES:
Standard 11-pin male connector.
Presence relay normally open
and nomally closed options. The
pulse relay is normally open
on arrival. Pulse relay can be
set to pulse on departure. Direct
replacement for Delta 816-9 |
See order form for prices |
24
Volts, Alternating Current
And Dual Relay Version |
|
3546-10 |
FEATURES:
This detector uses the 10-pin
Amphenol military connector.
Presence nomally open and closed
with the pulse relay normally
open on arrival. Pulse relay
can be set to pulse on departure.
Direct replacement for the Delta
816-10. |
See order form for prices |
Note: Please
select an 11-pin or 10-pin harness
to go with your Loop Detector
OC02-11 |
Industry
Standard - 11-pin connector
with 3 ft. lead |
See order form for prices |
MS01-10 |
MS01-10Amphenol
#MS3102A-18-1P Military screw
on 10-pin connector with 3
ft. lead for models 3546-1
and 3546-10 ONLY |
See order form for prices |
Please
call us at (661) 575-1100 or complete
our "More Information" form
if you would like to learn more
about Delta Scientific Corporation
or our product selection. |
|
|